 1.W-method Installation

W-method is usually used on plastic pipes with a diameter from 15mmto 100mm;

2. V-method Installation

V-method installation is the most widely used mode for daily measurement with pipe inner diameters ranging from 15 mm to 200 mmIt is also called reflective mode.

3.Z-method Installation

Z-method is commonly used when the pipe diameter is between 300mmand 500mm;